CHAPTER 9 INSTALLATION9-13COPYRIGHT © 1997 CANON INC. CANON NP6560/NP6360/NP6260 REV. 0 NOV. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)WorkInsert the drum rotating tool into thecut-in of the drum shaft. While holdingthe rotating tool so as to prevent thedrum from rotating counterclockwise,remove the drum fixing screw and thedrum fixing (cut-in member).1. If you let the drum to rotatecounterclockwise, the cleaningblade will not be in contact withthe drum correctly, causingcleaning faults. To prevent suchfaults, be sure to hold the drum inplace before removing the drumfixing screw.2. Do not expose the photosensitivedrum to light for longer than 30min.3. Do not ever expose thephotosensitive drum to directrays of the sun.4. Whenever placing thephotosensitive drum or theprocess unit outside themachine, be sure to cover it withsix or more sheets of copy paperto protect it against light.Slide out the fixing/feeding assemblywhile paying attention to the hopper.Place the drum protection sheet thatcomes with the machine to protectthe rubber roller of the registrationroller assembly and the drum.Slide out the process unit to the front,and insert the drum rotating tool thatcomes with the machine into thefront of the drum shaft; while rotatingthe drum clockwise, check to makesure that the drum is free of damage.Step111213RemarksCut-in Drum shaftRotating toolCaution: