320 Configuring Switching InformationTo display the GARP menu page, click Switching →GARP in the tree view.GARP TimersThe GARP Timers page contains fields for enabling GARP on the switch.To display the GARP Timers page, click Switching →GARP →GARP Timers in the tree view.Figure 7-36. GARP TimersThe GARP Timers page contains the following fields:• Interface — Specifies the Unit and Port or LAG on which the GARP timer is enabled.• GARP Join Timer (10–100) — Displays time, in centiseconds, that PDUs are transmitted. Thepossible field value is 10-100. The default value is 100 centisecs.• GARP Leave Timer (30–600) — Displays time lapse, in centiseconds, that the switch waits beforeleaving its GARP state. Leave time is activated by a Leave All Time message sent/received, andcancelled by the Join message received. Leave time must be greater than or equal to three times thejoin time. The possible field value is 30–600. The default value is 60 centisecs.• GARP Leave All Timer (200–6000) — Displays time lapse, in centiseconds, that all switches waitbefore leaving the GARP state. The leave all time must be greater than the leave time. The possiblefield value is 200–6000. The default value is 1000 centisecs.Defining GARP Timers1. Open the GARP Timers page.2. Complete the fields.3. Click Apply Changes.