9 Electrical CAMDVP-PM Application Manual9-4 Pulse Input TypeMPG Pulse Input Type Setting: D1864b9 b8 Pulse input type (positive logic) Explanation0 0FP fo rwa rd pu lse sRP r eve rse pu ls esDouble-phase(FP/RP)0 1FP p ul sesRP d ir ecti on (DIR) Fo rwa rd ru nn in g Re ver se r un ni ngSingle-phase(P/D)1 0FP A-phase pulsesRP B-phase pulsesReverse runningForward runningA/B phase(Singlefrequency)1 1FP A-phase pulsesRP B-phase pulsesReverse runningForward runningA/B phase(Quadruplefrequency) Pulse output TypePulse Output Type Setting: D1816/D1896/D1976B5 B4 Pulse output type (positive logic) Explanation0 0FP fo rwa rd pu lse sRP r eve rse pu ls esDouble-phase(FP/RP)0 1F P pulsesRP dir ection (DIR) F or war d r unning Reverse runningSingle-phase(P/D)1 0F P A -phase pulsesRP B- phas e pulsesF or war d r unni ng Revers e runningA/B phase(AB)9.2.1.4 Input /Output Magnification SettingDVP-PM provides E-CAM Data magnification function. When you input E-CAM Data as the below diagram,E-CAM Data can be magnified or minified by setting b0/b1 of D1816 (unit setting) as well as DD1858 (ElectronicGear Ratio), respectively controlling the output magnification and the input magnification