9 Electrical CAMDVP-PM Application Manual 9-171. D1846: Enabling cyclic E-CAM. Bit 13 = ON, cyclic E-CAM is enabled; bit 13 = OFF, cyclic E-CAM isdisabled.2. M1813: Completion of cyclic E-CAM. M1813 will be ON when cyclic E-CAM is completed. To restart thecyclic E-CAM, the user needs to reset this flag. Enabling acyclic E-CAM: D1846D1846: bit 14 = ON, acyclic E-CAM enabled; bit 14 = OFF, acyclic E-CAM disabled. Lower/higher bound of E-CAM synchronized output function: M1756, DD1838, DD18421. Operation Process when M1756 = ON: In flying saw / rotary cut application, set M1756 = ON to enablereference function. When Master position enters synchronized output section between PI and PII,CLR0 will be ON. When X0 is ON later, CLR0 switches off while CLR1 switches on. After this when X1is ON, CLR1 will be OFF.2. When M1756 is OFF with the condition: “D1839, D1838 (PI) ≦ CP of Master ≦ D1843, 1842 (PII)”,CLR0 will be ON.M1756=OFFM1756=ONClr0Clr1Clr0Clr1Targetposition(I)Targetposition(II)Master positionX0 On X1 OnMaster positionSlave speedSlave speedMaster position Completion of E-CAM initialization: M1812When E-CAM is enabled, DVP-PM will initialize the settings for E-CAM operation and M1812 will be ONwhen initialization is completed. The flag needs to be reset by the user. Times of acyclic E-CAM repetitions: D1832Times of acyclic E-CAM repetitions can be set in D1832. However, when the set value is bigger than H8000(b15=1), acyclic E-CAM will be switched into cyclic E-CAM automatically. In addition, if set value is 0,E-CAM Data will not be repeated. When set value is 1, E-CAM Data will be repeated once.