254. Construction and FunctionMANUAL CEAG AUtoMAtiC tEst systEM At-s+ 40071860177 (C) December 2016 www.ceag.deStatus-/ Failure LEDNetwork connectionRJ45Service PinConnection of the6-pole data cable tothe control unitCU CG-SServiceStörungFailure24V+ - PE+ – PE24 V DC fromDC/DC inverter.2Web module connectionThe CU-S+ control unitmust be removed if theweb module is updated.Comply with instructionsfor activation of the controlunit. Connect the ribboncable included with the webmodule here and route outthrough the ventilation slotsof the control unit housing.Then assemble the controlunit again and connect theweb module.4 4 7 WebmoduleThe webmodule is conform to EN 60950-1 anddeveloped, manufactured and tested according toDIN EN ISO 9001.Scope of applicationThe webmodule ZB-S is used for visualisation and moni-toring of an automatic test system AT-S+ via local ethernet(LAN) with a customary WEB-browser (e. g. InternetExplorerTM). Integrated mail-client for a comfortable andevent based failure notification for up to 5 email address-ees. Password protected access accounts capable ofparametrisation.MountingPay attention to temperatures outside the permittedrange during operation. The permissible ambient tempera-ture may not exceed 55°C.The module was designed for DIN rail mounting (2TE)to be only mounted in the cabinet. An external mountingoutside the AT-S+ cabinet is not permitted.Electrical connectionTechnical DataSupply voltage 24 V DCPower consumption < 1.5WConnection RJ 45Insulation class III, Degree of protection acc. toEN 60529: IP 20Ambient temperature -10°C ... +55°CConnection terminal 1.5 mm²Weight 0.1 kgDimensions H x W X D (in mm) 90 x 35 x 58