GE Multilin G30 Generator Protection System B-51APPENDIX B B.4 MEMORY MAPPINGBVT Fuse Failure Actuals (Read Only) (4 modules)A0AC VT Fuse Failure 1 V0 3rd Harmonic 0 to 999999.999 V 0.001 F060 0A0AE ...Repeated for module number 2A0B0 ...Repeated for module number 3A0B2 ...Repeated for module number 4Selector Switch Actual Values (Read Only)A210 Selector Switch 1 Position 1 to 7 --- 1 F001 0A211 Selector Switch 2 Position 1 to 7 --- 1 F001 1Selector Switch Settings (Read/Write) (2 modules)A280 Selector 1 Function 0 to 1 --- 1 F102 0 (Disabled)A281 Selector 1 Range 1 to 7 --- 1 F001 7A282 Selector 1 Timeout 3 to 60 s 0.1 F001 50A283 Selector 1 Step Up 0 to 4294967295 --- 1 F300 0A285 Selector 1 Step Mode 0 to 1 --- 1 F083 0 (Time-out)A286 Selector 1 Acknowledge 0 to 4294967295 --- 1 F300 0A288 Selector 1 Bit0 0 to 4294967295 --- 1 F300 0A28A Selector 1 Bit1 0 to 4294967295 --- 1 F300 0A28C Selector 1 Bit2 0 to 4294967295 --- 1 F300 0A28E Selector 1 Bit Mode 0 to 1 --- 1 F083 0 (Time-out)A28F Selector 1 Bit Acknowledge 0 to 4294967295 --- 1 F300 0A291 Selector 1 Power Up Mode 0 to 2 --- 1 F084 0 (Restore)A292 Selector 1 Target 0 to 2 --- 1 F109 0 (Self-reset)A293 Selector 1 Events 0 to 1 --- 1 F102 0 (Disabled)A294 Reserved (10 items) --- --- 1 F001 0A29E ...Repeated for Selector 2Digital Counter (Read/Write Setting) (8 modules)A300 Digital Counter 1 Function 0 to 1 --- 1 F102 0 (Disabled)A301 Digital Counter 1 Name --- --- --- F205 “Counter 1"A307 Digital Counter 1 Units --- --- --- F206 (none)A30A Digital Counter 1 Block 0 to 4294967295 --- 1 F300 0A30C Digital Counter 1 Up 0 to 4294967295 --- 1 F300 0A30E Digital Counter 1 Down 0 to 4294967295 --- 1 F300 0A311 Digital Counter 1 Preset –2147483647 to2147483647--- 1 F004 0A313 Digital Counter 1 Compare –2147483647 to2147483647 --- 1 F004 0A315 Digital Counter 1 Reset 0 to 4294967295 --- 1 F300 0A317 Digital Counter 1 Freeze/Reset 0 to 4294967295 --- 1 F300 0A319 Digital Counter 1 Freeze/Count 0 to 4294967295 --- 1 F300 0A31B Digital Counter 1 Set To Preset 0 to 4294967295 --- 1 F300 0A31D Reserved (11 items) --- --- --- F001 0A328 ...Repeated for Digital Counter 2A350 ...Repeated for Digital Counter 3A378 ...Repeated for Digital Counter 4A3A0 ...Repeated for Digital Counter 5A3C8 ...Repeated for Digital Counter 6A3F0 ...Repeated for Digital Counter 7A418 ...Repeated for Digital Counter 8Volts Per Hertz (Read/Write Grouped Setting) (2 modules)A580 Volts Per Hertz 1 Function 0 to 1 --- 1 F102 0 (Disabled)A581 Volts Per Hertz 1 Source 0 to 5 --- 1 F167 0 (SRC 1)A582 Volts Per Hertz 1 Pickup 0.8 to 4 pu 0.01 F001 80A583 Volts Per Hertz 1 Curves 0 to 7 --- 1 F240 0 (Definite Time)A584 Volts Per Hertz 1 TD Multiplier 0.05 to 600 --- 0.01 F001 100A585 Volts Per Hertz 1 Block 0 to 4294967295 --- 1 F300 0Table B–10: MODBUS MEMORY MAP (Sheet 43 of 64)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT