GE Multilin G30 Generator Protection System B-57APPENDIX B B.4 MEMORY MAPPINGBB376 ...Repeated for module number 3B379 ...Repeated for module number 4B37C ...Repeated for module number 5B37F ...Repeated for module number 6B382 ...Repeated for module number 7B385 ...Repeated for module number 8B388 ...Repeated for module number 9B38B ...Repeated for module number 10B38E ...Repeated for module number 11B391 ...Repeated for module number 12B394 ...Repeated for module number 13B397 ...Repeated for module number 14B39A ...Repeated for module number 15B39D ...Repeated for module number 16B3A0 ...Repeated for module number 17B3A3 ...Repeated for module number 18B3A6 ...Repeated for module number 19B3A9 ...Repeated for module number 20B3AC ...Repeated for module number 21B3AF ...Repeated for module number 22B3B2 ...Repeated for module number 23B3B5 ...Repeated for module number 24IEC 61850 XSWI Configuration (Read/Write Command) (24 modules)B372 Command to Clear XSWI OpCnt (Operation Counter) 0 to 1 --- 1 F126 0 (No)IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)B400 Number of Status Indications in GGIO1 8 to 128 --- 8 F001 8B402 IEC 61850 GGIO1 Indication FlexLogic operands (128items)0 to 4294967295 --- 1 F300 0IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)B5A0 IEC 61850 Configurable GOOSE Function (GoEna) 0 to 1 --- 1 F102 1 (Enabled)B5A1 IEC 61850 Configurable GOOSE ID --- --- --- F209 “GOOSEOut_x_”B5C2 Configurable GOOSE Destination MAC Address --- --- --- F072 0B5C5 IEC 61850 Configurable GOOSE VLAN Transmit Priority 0 to 7 --- 1 F001 4B5C6 IEC 61850 Configurable GOOSE VLAN ID 0 to 4095 --- 1 F001 0B5C7 IEC 61850 Configurable GOOSE ETYPE APPID 0 to 16383 --- 1 F001 0B5C8 IEC 61850 Configurable GOOSE ConfRev (ConfigurationRevision)1 to 4294967295 --- 1 F003 1B5CA IEC 61850 Configurable GOOSE Retransmission Curve 0 to 3 --- 1 F611 3 (Relaxed)B5CB Configurable GOOSE Dataset Items for Transmission(64 items)0 to 1008 --- 1 F616 0 (None)B60B ...Repeated for module number 2B676 ...Repeated for module number 3B6E1 ...Repeated for module number 4B74C ...Repeated for module number 5B7B7 ...Repeated for module number 6B822 ...Repeated for module number 7B88D ...Repeated for module number 8IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)B900 Configurable GOOSE Dataset Items for Reception(32 items)0 to 197 --- 1 F233 0 (None)B920 ...Repeated for module number 2B940 ...Repeated for module number 3B960 ...Repeated for module number 4B980 ...Repeated for module number 5B9A0 ...Repeated for module number 6Table B–10: MODBUS MEMORY MAP (Sheet 49 of 64)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT