GE Multilin G30 Generator Protection System B-69APPENDIX B B.4 MEMORY MAPPINGBD34E IEC 61850 GGIO2.CF.SPCSO47.ctlModel Value 0 to 2 --- 1 F001 1D34F IEC 61850 GGIO2.CF.SPCSO48.ctlModel Value 0 to 2 --- 1 F001 1D350 IEC 61850 GGIO2.CF.SPCSO49.ctlModel Value 0 to 2 --- 1 F001 1D351 IEC 61850 GGIO2.CF.SPCSO50.ctlModel Value 0 to 2 --- 1 F001 1D352 IEC 61850 GGIO2.CF.SPCSO51.ctlModel Value 0 to 2 --- 1 F001 1D353 IEC 61850 GGIO2.CF.SPCSO52.ctlModel Value 0 to 2 --- 1 F001 1D354 IEC 61850 GGIO2.CF.SPCSO53.ctlModel Value 0 to 2 --- 1 F001 1D355 IEC 61850 GGIO2.CF.SPCSO54.ctlModel Value 0 to 2 --- 1 F001 1D356 IEC 61850 GGIO2.CF.SPCSO55.ctlModel Value 0 to 2 --- 1 F001 1D357 IEC 61850 GGIO2.CF.SPCSO56.ctlModel Value 0 to 2 --- 1 F001 1D358 IEC 61850 GGIO2.CF.SPCSO57.ctlModel Value 0 to 2 --- 1 F001 1D359 IEC 61850 GGIO2.CF.SPCSO58.ctlModel Value 0 to 2 --- 1 F001 1D35A IEC 61850 GGIO2.CF.SPCSO59.ctlModel Value 0 to 2 --- 1 F001 1D35B IEC 61850 GGIO2.CF.SPCSO60.ctlModel Value 0 to 2 --- 1 F001 1D35C IEC 61850 GGIO2.CF.SPCSO61.ctlModel Value 0 to 2 --- 1 F001 1D35D IEC 61850 GGIO2.CF.SPCSO62.ctlModel Value 0 to 2 --- 1 F001 1D35E IEC 61850 GGIO2.CF.SPCSO63.ctlModel Value 0 to 2 --- 1 F001 1D35F IEC 61850 GGIO2.CF.SPCSO64.ctlModel Value 0 to 2 --- 1 F001 1Remote Device Status (Read Only) (16 modules)D360 Remote Device 1 StNum 0 to 4294967295 --- 1 F003 0D362 Remote Device 1 SqNum 0 to 4294967295 --- 1 F003 0D364 ...Repeated for Remote Device 2D368 ...Repeated for Remote Device 3D36C ...Repeated for Remote Device 4D370 ...Repeated for Remote Device 5D374 ...Repeated for Remote Device 6D378 ...Repeated for Remote Device 7D37C ...Repeated for Remote Device 8D380 ...Repeated for Remote Device 9D384 ...Repeated for Remote Device 10D388 ...Repeated for Remote Device 11D38C ...Repeated for Remote Device 12D390 ...Repeated for Remote Device 13D394 ...Repeated for Remote Device 14D398 ...Repeated for Remote Device 15D39C ...Repeated for Remote Device 16Contact Outputs (Read/Write Setting) (64 modules)D3E0 Contact Output 1 Name --- --- --- F205 “Cont Op 1"D3E6 Contact Output 1 Operation 0 to 4294967295 --- 1 F300 0D3E8 Contact Output 1 Seal In 0 to 4294967295 --- 1 F300 0D3EA Latching Output 1 Reset 0 to 4294967295 --- 1 F300 0D3EC Contact Output 1 Events 0 to 1 --- 1 F102 1 (Enabled)D3ED Latching Output 1 Type 0 to 1 --- 1 F090 0 (Operate-dominant)D3EE Reserved --- --- --- F001 0D3EF ...Repeated for Contact Output 2D3FE ...Repeated for Contact Output 3D40D ...Repeated for Contact Output 4D41C ...Repeated for Contact Output 5D42B ...Repeated for Contact Output 6D43A ...Repeated for Contact Output 7D449 ...Repeated for Contact Output 8D458 ...Repeated for Contact Output 9D467 ...Repeated for Contact Output 10Table B–10: MODBUS MEMORY MAP (Sheet 61 of 64)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT