System POST ErrorsIf POST (Power-On Self-Test) errors occur during startup, this error log helps isolatefaults when used with the diagnostics.Read System POST ErrorsVersion : 0Severity : 0Disposition : 0Initiator : 0Event being reported : 0Extended Error Log Data:0xC2 0x00 0x84 0x09 0x00 0x00 0x00 0x000x20 0x00 0x00 0x00 0x00 0x00 0x72 0x740x63 0x00 0x00 0x00 0x00 0x00 0x00 0x000x00 0x00 0x28 0x03 0x00 0x05 0x00 0x010x00 0x00 0x00 0x00 0x00 0x00 0x00 0x000x49 0x42 0x4D 0x00 0x55 0x30 0x2E 0x310x2D 0x50 0x31 0x2D 0x58 0x31 0x00(Press Return to Continue)Service Processor Operational PhasesThis section provides a high-level flow of the phases of the service processor.Pre-Standby PhaseThis phase is entered when the server is connected to a power source. The server mayor may not be fully powered on. This phase is exited when the Power-On Self-Tests(POST) and configuration tasks are completed.The Pre-Standby phase components are as follows:v Service Processor Initialization - Performs any necessary hardware and softwareinitializations.SP Power AppliedPre-Standby PhaseStandby Phase SP Menus AvailableBring-Up Phase SMS Menus AvailableRun-time Phase AIX Login Prompt AvailableChapter 3. Using the Service Processor 69