13-3DD Command table13CONTROL COMMAND00 — Send frequency data01 Same as Send mode datacommand 0602 — Read upper/lower frequencies forselected band03 — Read operating frequency04 — Read operating mode05 — Set operating frequency06 00 Select LSB01 Select USB02 Select AM03 Select CW04 Select FSK05 Select FM07 Select CW-R08 Select FSK-R11 Select S-AM(D)14 Select S-AM(L)15 Select S-AM(U)16 Select P2507 — Select (Last selected) VFO mode08 — Select memory mode0–1219* Select memory channel*0–999, 1000–1099 (A00–A99),1100–1199 (S00–S99),1200–1219 (P0A–P9A)0–12* Select memory bank*0–9, 10 (Bank-A), 11 (Bank-S),12 (Bank-P)09 — Memory write0A — Memory to VFO0B — Memory clear0C — Read offset frequency(see p. 13-10 for details)0D — Set offset frequency(see p. 13-10 for details)0E 00 Scan stop01 Programmed scan (Prog 0)/memory scan start02 Programmed scan (Prog 0) start03 ∂F scan start04 Auto memory write scan start12 Fine programmed scan start13 Fine ∂F scan start22 Memory scan start23 Select memory scan start24 Mode select memory scan start42 Priority scan (Prio 0) startA0 Set ∂F scan Fixed frequency ONAA Set ∂F scan Fixed frequency OFFA1–A7 Set ∂F scan span (A1=±5 kHz;A2=±10 kHz; A3=±20 kHz;A4=±50 kHz; A5=±100 kHz;A6=±500 kHz; A7=±1 MHz)B0 Set as non-select channelB1 Set as select channel(1–9=★(SEL)1–9; when no datacommand is specified, the previous-ly set number or “★1” is selected)B2 Set the number for select memoryscan (0=ALL; 1–9=★(SEL)1–9D0 Set scan resume OFF0E D1 Set scan resume ON(Close Timer)D3 Set scan resume ON(Close and Delay)10 Turn duplex OFF. (Simplex)11 Turn duplex ON. (DUP–)12 Turn duplex ON. (DUP+)10 00 Select 1 Hz tuning step01 Select 10 Hz tuning step02 Select 100 Hz tuning step03 Select 1 kHz tuning step04 Select 2.5 kHz tuning step05 Select 5 kHz tuning step06 Select 6.25 kHz tuning step07 Select 9 kHz tuning step08 Select 10 kHz tuning step09 Select 12.5 kHz tuning step10 Select 20 kHz tuning step11 Select 25 kHz tuning step12 Select 100 kHz tuning step13 Select 1 MHz tuning step14 Select Prog tuning step11 — Select/read attenuator (00=OFF;06=6 dB; 10=10 dB; 12=12 dB;18=18 dB; 20=20 dB; 24=24 dB;30=30 dB)12 00 Select/read the antenna below01 30 MHz. (00=HF ANT1,02 01=HF ANT2, 02=HF ANT3)13 00 Announce with voice synthesizer01 (00=all data; 01=frequency and02 S-meter level; 02=receive mode)14 01 + Level data [AF] level setting(0=max. CCW to 255=max. CW)02 + Level data [RF] level setting(0=max. CCW to 255=11 o’clock)03 + Level data [SQL] level setting(0=11 o’clock to 255=max. CW)06 + Level data [NR] level setting(0=min. to 255=max.)07 + Level data Left [TWIN PBT] setting or IF shiftsetting (0=max. CCW, 128=center,255=max. CW)08 + Level data Right [TWIN PBT] setting(0=max. CCW, 128=center,255=max. CW)09 + Level data [CW PITCH] setting(0=300 Hz, 128=600 Hz,255=900 Hz; 5 Hz steps)0D + Level data [NOTCH1] setting(0=low freq. to 255=high freq.)11 + Level data [AGC] control setting (0=max.CCW to 255=max. CW)12 + Level data [NB] control setting(0=max. CCW to 255=max. CW)18 + Level data [CONTRAST] setting (0=max.CCW to 255=max. CW)19 + Level data [BRIGHT] setting(0=max. CCW to 255=max. CW)1A + Level data [NOTCH2] setting(0=low freq. to 255=high freq.)1B + Level data [BASS] setting(0=max. CCW to 255=max. CW)1C + Level data [TREBLE] setting(0=max. CCW to 255=max. CW)Command Sub command Description Command Sub command Description