Page 2-12 V10/V7.5/V5/V3.5 Installation and Operation ManualIssue 3.5 Section 2 Preparation for Use and Installation2.2.15.1 RF Monitor SamplesA true sample of the RF output voltage isprovided on the RF power probeassembly’s (A42) RF MONITOR BNCconnector (J3) at the output of thetransmitter. This output should be appliedto a modulation monitor with 50 Ω inputimpedance. It may also be monitored byan oscilloscope during maintenanceprocedures. Nominal levels (for ratedpower) are as follows:Transmitter, Mode, Power RF MonitorV10, FM, 10,000 W 2.5 VV10, FM+HD, 7,300 W 2.2 VV10, HD, 2,800 W 2.2 VV7.5, FM, 7,500 W 2.2 VV7.5, FM+HD, 5,480 W 1.9 VV7.5, HD, 2,100 W 1.9 VV5, FM, 5,000 W 1.7 VV5, FM+HD, 3,650 W 1.6 VV5, HD, 1,400 W 1.6 VV3.5, FM, 3,750 W 1.5 VV3.5, FM+HD, 2,740 W 1.4 VV3.5, HD, 1,050 W 1.4 VTrue samples of the IPA amplifier(s)output voltage are provided on the IPAsplitter’s (A21 and A22, if applicable) IPARF MONITOR BNC connector (J3) at therear of the transmitter. These outputsshould be applied to a modulation monitorwith 50 Ω input impedance. Nominallevels (based on required IPA power) areas follows:Transmitter, Mode, Power IPAMonitorV10, FM, 10,000 W (250 W IPA) 1.0 VV10, FM+HD, 7,300 W 0.4 VV10, HD, 2,800 W 0.4 VV7.5, FM, 7,500 W (250 W IPA) 1.0 VV7.5, FM+HD, 5,480 W 0.4 VV7.5, HD, 2,100 W 0.4 VV5, FM, 5,000 W (250 W IPA) 1.0 VV5, FM+HD, 3,650 W 0.2 VV5, HD, 1,400 W 0.3 VV3.5, FM, 3,750 W (250 W IPA) 1.0 VV3.5, FM+HD, 2,740 W 0.2 VV3.5, HD, 1,050 W 0.3 VTable 2-4: Remote Monitor Connections(TB1, J4 or J6 of remote interface PWB)Remote Alarm, Statusor Sample Terminal or PinSummary Alarm TB1-4Interlock Open Alarm TB1-5Low Battery/Memory Fail TB1-6Low RF Alarm TB1-7Changeover Alarm TB1-8PA Fail Alarm TB1-9High Reflected Power Alarm TB1-10High Temperature Alarm TB1-11Transmitter Ready TB1-13RF On Status TB1-14Exciter Status TB1-15IPA Status TB1-16+15 V dc supply TB1-18Forward Power Sample TB1-20Reflected Power Sample TB1-21Ground TB1-3,12,17,19Preset 1 Status J4-15Preset 2 Status J4-16Preset 3 Status J4-17Preset 4 Status J4-18Preset 5 Status J4-19Preset 6 Status J4-20Remote Status J4-22IPA Power Supply Status J4-23Fan Supply Status J4-24Valid Data Status J4-26Ground J4-1,14,21,33,34,35Ac Fault Alarm J6-1Power Supply Fail Alarm J6-2IPA/RF Fail Alarm J6-3PA Voltage Sample J6-9Exciter Forward Pwr Sample J6-10Intake Air Temp Sample J6-11Exhaust Air Temp Sample J6-12Total PA Current Sample J6-21Ground J6-7,8,13,14,20,33