Page 3-24 V10/V7.5/V5/V3.5 Installation and Operation ManualIssue 3.5 Section 3 Operating Instructions(b) Use f and g to scroll through PAModules A - H and IPA modules A and Bfor V10; A - C, E - G and IPA modules Aand B for V7.5; A - D and IPA module forV5; or A - C and IPA module for V3.5. IfOffline is flashing on the display, theassociated module is not connected orhas been removed.NOTEIn V5/V3.5 transmitters with a dual PA IPAmodule, the Curr. indication for the inactivePA will appear as DSBL (flashing).(c) Press Reset to attempt to clear faultsassociated with RF power modules andtheir switching power supplies.(d) Press Back to return to previous screen.3.6.6 View Events LogThe most recent 100 transmitter events(alarms, operational changes, etc.) are storedin memory. View the events log as follows:(a) From the main menu, highlight EventsLog (using f and g) and press Select.A list of events (1 is the most recent) willbe displayed, sorted by date and time,with a description of the event.(b) Press f or g to scroll through theevents. Press Alarms Only to displayonly fault occurrences. Press Select on ahighlighted event to display thetransmitter status when the highlightedevent occurred.(c) In the event summary screen, there arefive screens of information, viewable byusing the f and g and Select buttons.These screens provide snapshots of thepreset (see 3.6.4), changeover (see3.6.13), meters (see main screen, 3.6.2),alarms (see 3.6.3) and module (see3.6.5) screens at the time of the event.(d) To clear the events log, press Clear Log.The following text will be displayed:WARNING: You are about to erase theevents log. Press Yes to erase theevents log.(e) Press Back to return to previous screen.3.6.7 View Software Version(a) Press Back to return to previous screen.Main MenuPower ControlModule StatusEvents LogSoftware VersionMeters PresetsClear Select Back11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanAMain MenuPower ControlModule StatusEvents LogSoftware VersionMeters PresetsClear Select Back11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanAEvents Log1 25MAY06 11:01:12 LCL Cmd RF OFF2 25MAY06 10:58:12 Low Fwd Pwr3 25MAY06 10:58:12 PS Fail D4 25MAY06 10:58:12 PS Fail C5 25MAY06 10:58:12 PS Fail BAlarms Only Select Back11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanAEvents Log1 25MAY06 11:01:12 LCL Cmd RF OFF2 25MAY06 10:58:12 Low Fwd Pwr3 25MAY06 10:58:12 PS Fail D4 25MAY06 10:58:12 PS Fail C5 25MAY06 10:58:12 PS Fail BAlarms Only Select Back11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA1 25MAY06 11:01:12 LCL Cmd RF OFFPreset Summary LOCALChangeover Summary RF OFFMeters SummaryAlarms SummaryModule SummarySelect Back11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA1 25MAY06 11:01:12 LCL Cmd RF OFFPreset Summary LOCALChangeover Summary RF OFFMeters SummaryAlarms SummaryModule SummarySelect Back11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanAMain MenuPower ControlModule StatusEvents LogSoftware VersionMeters PresetsSelect Back11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanAMain MenuPower ControlModule StatusEvents LogSoftware VersionMeters PresetsSelect Back11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanAGeneric screenshown forreference onlySoftware VersionVirtuoso V5 FM TransmitterV5 x.x Release x Build xMONTH DAY YEAR TIMENautel LimitedBack11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanASoftware VersionVirtuoso V5 FM TransmitterV5 x.x Release x Build xMONTH DAY YEAR TIMENautel LimitedBack11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA