Operation Patterns5-45.2 JOG Operation5.2.1 Settings and Operations of JOG OperationThe parameters for JOG operations are specified in the positioning parameter setting menusof Configuration PMX.Pulses are output while the JOG operation start instruction (F381 JOGST) is executed. Operation diagramt [ms]f [Hz]100ms20,000Hz1,000HzInstruction start conditionBusy signalOperation done signal200msJOG operation target speed 20,000 Operations of each contact• The BUSY flags (X808 to X80B), which indicate that the motor is running, will turn on whenthe JOG operation starts, and they will turn off when the operation completes.• The operation done flags (X810 to X813), which indicate the completion of operation, willturn on when the current operation is completed, and they will be held until the nextpositioning control, JOG operation or home return operation starts. Programming cautions• The startup contact and flag numbers vary depending on channel numbers (axis numbers).