Technical InformationPJLink protocolThe network function of the projector supports PJLink class 1, and the PJLink protocol can be used to performprojector setting and projector status query operations from a computer.Control commandsThe following table lists the PJLink protocol commands that can be used to control the projector.f x characters in tables are non-specific characters.Command Control details Parameter / return string RemarkPOWR Power supply control 01StandbyPower onPOWR ? Power supply status query0123StandbyPower onCool-down in progressWarm-up in progressINPT Input selection1112213132415152COMPUTER1COMPUTER2VIDEOHDMI1HDMI2MEMORY VIEWERNETWORKUSB DISPLAYINPT ? Input selection queryAVMT AV MUTE control *1 3031AV mute function disabled (off)AV mute function enabled (on)AVMT ? AV MUTE status queryERST ? Error status query ××××××1st byte Indicates fan errors, andreturns 0 or 2f 0 = No error knownf 1 = Warningf 2 = Error2nd byte Indicates luminous lamperrors, and returns 0 – 23rd byte Indicates temperature er-rors, and returns 0 – 24th byte Indicates cover open er-rors, and returns 0 or 25th byte Indicates filter errors, andreturns 0 – 26th byte Indicates other errors,and returns 0 or 2LAMP ? Luminous lamp statusquery ×××××× 1st number (1 – 5 digits) : Total usage time of luminous lamp2nd number : 0 = Luminous lamp off, 1 = Lumious lamp onINST ? Input selection list query 11 12 21 31 32 41 51 52NAME ? Projector name query ××××× Returns the projector name set in [NAME CHANGE] of[NETWORK/USB].INF1 ? Manufacturer name query Panasonic Returns manufacturer name.INF2 ? Model name query VW360VX430 Returns model name.INF0 ? Other information query ××××× Returns information such as version number.CLSS ? Class information query 1 Returns class for PJLink.*1 When the [PROJECTOR SETUP] menu → [ECO MANAGEMENT] → [AV MUTE DETECTION] is set to [ON], do not switch on/off in ashort time.PJLink security authenticationThe password used for PJLink is the same as that of the password set for web control.When using the projector without security authentication, do not set a password for web control.f For specifications related to PJLink, refer to the website of Japan Business Machine and Information SystemIndustries Association.URL http://pjlink.jbmia.or.jp/english/122 - ENGLISHChapter 7 Appendix - Technical Information