Maintenance4-133160-A2-GB22-10 December 1996Table 4-3Valid Send Test Pattern CombinationsQRSS (Network) QRSS (Port) 1 in 8 (Network) 511 (Port)QRSS (Network) N/A NO NO NOQRSS (Port) NO YES (onseparate ports)N/A YES (onseparate ports)1 in 8 (Network) NO NO N/A NO511 (Port) NO N/A N/A YES (onseparate ports)Monitoring Test PatternsUse the Monitor command to monitor a QRSS testpattern over all the channels on the network interface, orto monitor QRSS or 511 test patterns on the channelsallocated to an individual port.This command provides the number of errors detectedin the test pattern (5 digits, maximum 99999).To monitor a QRSS or 511 test pattern,1. Press F2 to select Test from the top-level menuscreen.F1DS U E SFStat Test CnfigF2 F32. From the Test screen, press F3 to select Ptrns.F1Test:Rlpbk Lpbk PtrnsF2 F33. From the Patterns screen, press F3 to select Mon.F1Patterns:Abort Send MonF2 F34. From the Patterns Mon screen, press F1 for QRSSor F2 for 511.F1Patterns: MonQRSS 511F2 F35. From the Monitor screen, press the function keythat corresponds to the network or port for whichyou want to monitor a test pattern. Use the scrollkeys, if necessary. (NET does not appear for the511 pattern.)F1Monitor:NameNET Prt1 Prt2F2 F3The Monitor screen appears with the error count.If the maximum of 99999 is exceeded, OvrFlwappears instead of the count. If the receiver losessynchronization while the monitor is active,No Sync appears.