OfficeServ 7100 PROGRAMMINGTECHNICAL MANUAL PART 2 JANUARY 2009MMC: 838 PRIVATE IP ADDRESSDESCRIPTION:This optional MMC provides a means for the MP10/MP10a to communicate withremote VoIP gateways on a network consisting of a mixture of private and public IPaddresses. If your network consists of IP addressing that is entirely private ORentirely public, you do not need to utilize this MMC. There are 80 entries.¾ NOTE: When changing any IP address/value, listed below, three digits mustbe input for each (octet) field. Example 192.168.1.10 input must be: 192 168001 010PROGRAM KEYSUP & DOWN Used to scroll through optionsKEYPAD Used to enter selectionsSOFT KEYS Move cursor left and rightSPEAKER Used to store data and advance to next MMCACTION DISPLAY1. Press TRANSFER 838.Display shows the first available option.PRIVATE IP (01)0. 0. 0. 0Press UP or DOWN key to select an entryORPress the RIGHT soft key to move cursor.2. Press UP or DOWN key to select an optionORPRIVATE IP (01)0. 0. 0. 0Press RIGHT soft key to move cursor.3. Enter IP address in 3 digit entry format. IE105.52.10.20 is input 105.052.010.020.PRIVATE IP (01)105. 052. 010.020Press RIGHT soft key to enter data andmove cursor to the Step 1 position.4. Press UP or DOWN key to select anotherentry OR Press RIGHT soft key to movePRIVATE IP (01)105. 052. 010.020cursorORPress TRANSFER to store and exit OR pressSPEAKER to store and advance to next MMC.PRIVATE IP (01)105. 052. 010.020