OfficeServ 7100 PROGRAMMINGTECHNICAL MANUAL PART 2 APRIL 2007MMC: 852ALMNO.ALMCODE ALARM DEFINITION79 MNF 19 SLI RecoveryAn SLI card detected as out of servicehas been detected as recovered and isin service via internal CODEC test.Alarm Data = Cabinet, Slot Port (C1,2)(S1 through 10)(P1 through24)80 MNF 20 PSU B Alarm A second PSUB is required81 MNF 21 DSS Alarm The number of DSS units has beenexceeded82 MNF 26 SIO RxQ Over The SIO receive buffer is over 80% full83 MNF 27 SIO RxQ Under The SIO receive buffer is back under80% full84 MNF 28 LAN Printer Err A LAN printer has lost communication85 MNF 29 LAN Printer Rec A LAN printer has recoveredcommunication86 MNG 01 Phone Disconnect87 MNG 02 Phone Connect88 MNG 03 OFF Hook Alarm89 MNG 04 On Hook90 MNG 05 MGI Packet Loss91 MNG 06 MGI Packet Delay