WEC8500/WEC8050 (APC) Operation Manual v10.1 135©Samsung Electronics America6 To check the configured AP profile, execute the ‘show ap detail[AP_PROFILE_ NAME]’ command.Configuration using Web UI1 By referring to the ‘APC List Management’, add the APC list that will beused as a backup APC.2 In the menu bar of , select andthen select the menu in the sub-menus. Operator can add or delete the APC list that will be used forredundancy. If necessary, operator can configure the fallback function.Figure 95. Redundancy Configuration WindowParameter DescriptionAPC NAME Name of an APC to be added or deleted to/from redundancyThe APC must be an APC registered in the APC list.MAC ADDRESS Because this is a MAC address configured during registration to theAPC list, an operator does not have to enter this at the redundancyconfiguration stage.IP_ADDRESS IP address of an APC to addThis address is an IP required by an AP to connect to the APC.Therefore, you must enter the AP Management IP address of theAPC.PORT CAPWAP PORT number of the APC to addIf no port number is entered, it is set to 5246, the default port numberof CAPWAP protocol. It is recommended not to use a different portnumber if it is specially required.PUBLIC_IP_ADDRESSPUBLIC IP address of the APC to addThis address is an IP required by an AP to connect to the APC. Ifthe APC is in the NAT environment, you must enter an official IPconfigured in the NAT instead of the private IP of APC.PUBLIC_PORT PUBLIC CAPWAP PORT number of the APC to addThis port number is required by an AP to connect to the APC. If the