WEC8500/WEC8050 (APC) Operation Manual v10.1 43©Samsung Electronics AmericaChapter 3 Data Network FunctionIn this chapter, how to set up the data network functions of APC including VLAN, linkaggregation, and layer 3 protocol is described.Port ConfigurationThe APC port is configured with a physical interface.• Physical interface of 11 ports except WEC8500 console port• Physical interface of 4 ports except WEC8050 console portPort ManagementThe WEC8500 Management port is used to manage the WEC8500. It doesnot support VLAN and its interface name is ‘mgmt0’. The 8 ports at the rightside of Management port are 10/100/1000 BASE T-ports and their namesare GE1-8.To the right side of the 10/100/1000 BASE T-ports, there are two Gigabitports, that is XE1 and XE2. In case of WEC8050, there is no management(mgmt0) port, connect the Ethernet cable to the port in one of ports ge1 toge4.Configuration using CLITo configure the port related function, enter into the interface mode by entering the‘interface [INTERFACE_NAME]’ command in the configure mode.An example of entering into the interface setup mode of the management port is shownbelow.WEC8500# configure terminalWEC8500/configure# interface mgmt0WEC8500/configure/interface mgmt0#The port related CLI commands are as follows:[auto-nego, speed, duplex]The commands used to configure an auto-nego, speed, and duplex addresses are shownbelow. To delete the configuration, enter the ‘no’ parameter.WEC8500/configure/interface ge1# speed-duplex ?10-full Set 10Mb/s full-duplex10-half Set 10Mb/s half-duplex100-full Set 100Mb/s full-duplex100-half Set 100Mb/s half-duplex1000-full Set 1000Mb/s full-duplex1000-half Set 1000Mb/s half-duplexauto-nego Set auto negotiation speed/duplex