September 2015 Service ManualTelematics Connector Pin LegendPart No. 218700 ZX-135/70 265Genie installed Telematics connector is wired with an Active High digital input.Connector Pin NumberingNote: A Deutsch plug p/n DT06-08SA mates with the Genie Telematics connectorPin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case1 System Power 12 VDC5 Amp Max. alloweddrawBattery Positive – constant power Supply power to device2 System Ground 0 VDC Battery Negative Device Ground3 Digital Output 1 12 VDC Engine Run Hour Meter12V = engine run, 0V = engine offMonitor Engine Hours4 Digital Output 2 12 VDC Key Switch Activation12V = key switch on, 0V = key switchoffMonitor machine utilization5 Digital Output 3 12 VDC Foot switch12V = active, 0V = inactiveMonitor machine utilization6 Digital Input 1 12 VDC Remote Disable Engine Start Remotely Prevent Engine Start7* Databus H CAN HIGH Genie Databus J1939 Engine Messages, ReceiveProprietary Genie TelematicsMessage8* Databus L CAN LOW Genie Databus J1939 Engine Messages, ReceiveProprietary Genie TelematicsMessage* Tier IV engine models only, J1939 engine message available.* Genie proprietary databus support.Wireless CertificationsTelematic device(s) should comply with specific wireless carrier certifications where applicable and comply with thefollowing:North America PTCRB, FCC/ICEurope CE, R&TTE