UniPOS IFS7002 two signal loopsInstruction Manual Page 11Revision 11/01.17 Of 145 Entering inspection time period (see section 8.3.1); Forced proceeding from phase Fire condition stage I to phase Fire condition stage II (seesection 8.3.3); Suppressing the local sounder (see sections 8.3.2 and 9.3.1); Displaying text messages from the inputs (see section 12.2.4); Displaying program data for the fire control panel (see sections 12.2.6 to 12.2.9 and12.2.11); Displaying the status of the addressable devices in the loops (see section 12.2.10); Displaying the archive (see section 12.2.12).All light indicators are visible.6.1.2. Access Level 2The personnel in charge of the fire protection have access to level 2; they shall be authorized andtrained to operate the fire control panel in the following conditions: Duty Mode; Fire condition; Fault condition; Disabled component; Information and adjustment.To enter Access level 2 use your password.The following features of the fire control panel are accessible: All features accessible at Level 1; Switching off the outputs, activated upon fire condition (see section 8.3.4); Exit of Fire condition (see section 8.3.5); System functions of the fire control panel (see section 12.3).6.1.3. Access Level 3Accessible for personnel trained and authorized for: Reconfiguration of specific data – of the protected site or of the fire control panel – savedin the memory; Maintenance of the fire control panel.This level has two sublevels of access - 3A and 3B.Level 3, sublevel 3A, is accessed through a password entered at Access level 2. At this sublevelthe functions for reconfiguration of specific data for the protected site or the fire control panel areaccessible (see section 13).Level 3, sublevel 3B is accessed when the fire control panel is opened. The following features areaccessible: Replacing a burnt fuse; Connecting fire alarm loops and executive devices.6.1.4. Access Level 4Accessible for personnel trained and authorized by the Producer to repair the fire control paneland to modify the software. Special means are required to enter this level.6.2. Indications and buttons for controlTable 1 gives detail description of the indications for each status, Table 2 presents the basicmeans for control. Appendix 1 shows the front panel of IFS7002.Table 1Conditions of the fire control panel IndicationAll conditions -The fire control panel is power suppliedIndicator Power supply –continuous green lightFire condition Common indicator Fire condition –flashing red light