UniPOS IFS7002 two signal loopsInstruction Manual Page 27Revision 11/01.17 Of 145 Occurred events (with the exception of triggered isolator in the zone) are not saved in theenergy independent memory; The zone is being automatically reset every 60 s (detectors in fire condition receive acommand to reset the fire)11.2. Indicators11.2.1. LEDs and sound indicatorsThe common indicator for Test Condition (Test) illuminates in continuous yellow light.Sound signaling is not supported for this condition.11.2.2. Text messagesTo display the text messages for fire alarm zones in test condition enter Information and ControlMode (see section 12.2.3).11.3. Using the keypadFor Test Condition 1 active button is supported. Where the fire control panel operates incombination of other conditions, their buttons are active too.Press the Menu button to enter Information and Control Mode.12. Information and Control Mode12.1. DescriptionInformation and Control Mode provides the user with the possibilities to display informationassociated with the fire control panel, and to enter control data.To enter Information and Control Mode, press button on the screen for Duty Mode, FireCondition, Fault Condition (with the exception of the screen for fatal error), Test Mode or Disabledcomponent.No specific LEDs or sound indication is provided for Information and Control Mode.Where the fire control panel operates in combination of Information and Control Mode and FaultCondition, button (Stop Alarm) is active too. Where the fire control panel operates incombination of Information and Control Mode and Fire Condition, buttons (Stop Alarm),(Outputs) and (Inspection) are active; and at Access Level 2 is active button (ResetFire).The screens visualized on the display are organized in a tree structure, containing subordinatemenus (Appendix 2а). Transition to a lower hierarchy menu is performed by the means of button(Enter); to revert to an upper hierarchy menu use button (Cancel). To switch betweenelements of one menu use buttons (Up) and (Down), when the menu is displayed as anascending window from the bottom left corner of the screen, or use buttons (Move Up) and(Move Down), when the menu is displayed as a panel in the middle of the screen. To exit thecondition press button (Exit) or button (Cancel) until you exit the main menu.When you enter Information and Control Mode, transition to the first menu is being carried out.The first menu contains three subordinate menus, requiring separate access levels: Lists – Access Level 1; System functions – Access Level 2; SetUp – Access Level 3.