Chapter 3 Wiring ASDA-A2R SeriesRevision December, 2014 3-39C15: Encoder OCZ output (open-collector Z pulse output)3.3.4 The DI and DO Signal Specified by the UserIf the default setting of DI/DO signal cannot satisfy the need, self-set the DI/DO signal willdo and easy. The signal function of DI1 ~ 8 and DO1 ~ 5 is determined by parameterP2-10 ~ P2-17 and parameter P2-18 ~ P2-22 respectively. Please refer to Chapter 7.2,which shown as the following table. Enter DI or DO code in the corresponding parameterto setup DI/DO.Signal Name Pin No CorrespondingParameter Signal Name Pin No CorrespondingParameterStandardDIDI1- CN1-9 P2-10StandardDODO1+ CN1-7 P2-18DI2- CN1-10 P2-11 DO1- CN1-6DI3- CN1-34 P2-12 DO2+ CN1-5 P2-19DI4- CN1-8 P2-13 DO2- CN1-4DI5- CN1-33 P2-14 DO3+ CN1-3 P2-20DI6- CN1-32 P2-15 DO3- CN1-2DI7- CN1-31 P2-16 DO4+ CN1-1 P2-21DI8- CN1-30 P2-17 DO4- CN1-26ExtensionDI(Optional)EDI9 CN7-2 P2-36 DO5+ CN1-28 P2-22EDI10 CN7-3 P2-37 DO5- CN1-27EDI11 CN7-4 P2-38EDI12 CN7-5 P2-39EDI13 CN7-6 P2-40EDI14 CN7-7 P2-41