30 DC motor driver module XN-322-1DCD-B3530.3 Wiring244 XN300 slice modules 06/16 MN050002 EN www.eaton.comKeep the ratio of the period duration to the sequence time in mindOutput signal when the period duration is set correctlyt p = t OutputSequencePeriod duration tP will be equal to the time that the output sequence lasts.NOTICESelect period duration tp in line with the output sequence:t p = t OutputSequence = t OutputSequence1 +... + t OutputSequence4Failure to do so may result in undesired XN300 slice modulestates.