P446SV Appendix B -Settings and SignalsP446SV-TM-EN-1 B77MENU TEXT COL ROW DEFAULT SETTING AVAILABLE OPTIONSDESCRIPTIONremain ‘high’ as long as key is pressed.Fn Key 9 Label 17 1C Function Key 1 From 32 to 163 in steps of 1[ASCII Text (16 chars)]Allows the text of the function key to be changed to something more suitable for the application.Fn Key 10 17 1D UnlockedDisabledUnlocked (Enabled)Locked[Indexed String]Setting to activate function key. The ‘Lock’ setting allows a function key output that is set to toggle mode to be locked in its current activeposition.Fn Key 10 Mode 17 1E NormalNormalToggled[Indexed String]Sets the function key in toggle or normal mode. In ‘Toggle’ mode, a single key press will set/latch the function key output as ‘high’ or ‘low’ inprogrammable scheme logic. This feature can be used to enable/disable relay functions. In the ‘Normal’ mode the function key output willremain ‘high’ as long as key is pressed.Fn Key 10 Label 17 1F Function Key 1 From 32 to 163 in steps of 1[ASCII Text (16 chars)]Allows the text of the function key to be changed to something more suitable for the application.IEC 61850-9.2LE 18 00This column contains all the configure/setting measurement parameters relative to IEC 61850-9-2LE.Physical Link 18 01 Fibre Optic 0 or 1[Indexed String]AntiAlias Filter 18 02 EnabledDisabledEnabled[Indexed String]Synchro Alarm 18 03 Local 1PPS From 0 to 2 in steps of 1[Indexed String]SV Test Mode 18 04 Disabled 0 or 1[Indexed String]This setting is used for processing Sampled Value frames with an IEC 61850 Test mode flag. This setting is common to all SV Logical Nodesconfigured in the IED.Disabled: all channel data frames received with an IEC 61850 Test flag are treated as invalid. The IED blocks relevant protection functionsEnabled: all channel data frames received with an IEC 61850 Test flag are treated as good so all protection functions remain active.Note: The cell ‘9.2 Mode’ used in software prior to IEC 61850 edition 2 has been renamed as ‘SV Test Mode’Merge Unit Delay 18 05 1 From 0 to 3 in steps of 0.25[Numeric(time-ms)]VT Switch Mode 18 06 Disabled 0 or 1[Indexed String]LN Count 18 11 1 From 1 to 8 in steps of 1[Integers]LN1 Name 18 12 MiCOM Logical Node 1LN2 Name 18 13 MiCOM Logical Node 2LN3 Name 18 14 MiCOM Logical Node 3LN4 Name 18 15 MiCOM Logical Node 4LN5 Name 18 16 MiCOM Logical Node 5LN6 Name 18 17 MiCOM Logical Node 6