Table 3. Firmware Error Codes. (continued)Error Code Description Action / Possible Failing FRU25Cyy006 Memory DIMM failed inter-extent test. 1. Replace the memory card.Location: P1-M12. Replace the processor card.Location: P1-C1Location: P1-C2See Memory Error Notes on page 120for more information.25Cyy007 Memory DIMM failed extent access test. 1. Replace the memory card.Location: P1-M12. Replace the processor card.Location: P1-C1Location: P1-C2See Memory Error Notes on page 120for more information.25Cyy008 Memory DIMM has been deconfigured. 1. Use the memory config/deconfigmenu in the Service ProcessorSystem Information Menu to checkthe status of the memory DIMMs.2. Go to “MAP 1240: MemoryProblem Resolution” on page 45.26020001 Invalid PCI adapter vendor ID. 1. Move adapter to another slot(behind another PCI bridge).2. Check for available firmwareupdates for adapter. Apply updateif available.3. Run AIX diagnostics on adapter.Replace if indicated.4. Replace adapter.5. Check for system firmwareupdates. Apply if update available.6. Replace system board.Location: P1(See note 3 on page 109.)Chapter 5. Error Code to FRU Index 121