Table 3. Firmware Error Codes. (continued)Error Code Description Action / Possible Failing FRU40100005 Loss of system power detected. 1. Possible temporary AC power loss.Turn on the power. If the systemboots, use the AIX Service Aids toreset the System Attentionindicator and the Lightpathindicators. On your next shutdownand prior to reboot, use theservice processor menus to resetthe error log.2. If AC power is available to system,replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V340100006 Loss of ac power to system detected. 1. Possible temporary AC power loss.Turn on the power. If the systemboots, use the AIX Service Aids toreset the System Attentionindicator and the Lightpathindicators. On your next shutdownand prior to reboot, use theservice processor menus to resetthe error log.2. If AC power is available to system,replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V340100007 Immediate shutdown due to loss of AC tosystem. 1. Possible temporary AC power loss.Turn on the power. If the systemboots, use the AIX Service Aids toreset the System Attentionindicator and the Lightpathindicators. On your next shutdownand prior to reboot, use theservice processor menus to resetthe error log.2. If AC power is available to system,replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V3Chapter 5. Error Code to FRU Index 135