Table 3. Firmware Error Codes. (continued)Error Code Description Action / Possible Failing FRU40110008 Thermal failure detected in power supplymain enclosure.1. If a location code is displayed withthis error code, replace the part atthat location.2. Look at the service processor errorlog for more error information.3. Reseat the power supplies4. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V340110009 Overvoltage detected on 5 volt line inpower supply main enclosure1. If a location code is displayed withthis error code, replace the part atthat location.2. Look at the service processor errorlog for more error information.3. Reseat the power supplies4. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V34011000A Overvoltage detected on 5 volt line inpower supply main enclosure1. If a location code is displayed withthis error code, replace the part atthat location.2. Look at the service processor errorlog for more error information.3. Reseat the power supplies4. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V34011000B Overvoltage detected on 5 volt line inpower supply main enclosure1. If a location code is displayed withthis error code, replace the part atthat location.2. Look at the service processor errorlog for more error information.3. Reseat the power supplies4. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V3138 Service Guide