Table 3. Firmware Error Codes. (continued)Error Code Description Action / Possible Failing FRU40112082 Low 5.0 voltage reading detected 1. If a location code is displayed withthis error code, replace the part atthat location.2. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V33. Replace the processor cards.Location: P1-C1Location: P1-C240112092 Low 3.3 V reading detected 1. If a location code is displayed withthis error code, replace the part atthat location.2. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V33. Replace the system board.Location: P1(See note 3 on page 109.)40112093 Low 2.5 V reading detected 1. If a location code is displayed withthis error code, replace the part atthat location.2. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V33. Replace the processor cards.Location: P1-C1Location: P1-C2401120B2 A low +12 voltage was detected 1. If a location code is displayed withthis error code, replace the part atthat location.2. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V33. Replace the system board.Location: P1(See note 3 on page 109.)Chapter 5. Error Code to FRU Index 149