Table 3. Firmware Error Codes. (continued)Error Code Description Action / Possible Failing FRU40110000 Loss of a redundant power supply wasdetected1. If a location code is displayed withthis error code, replace the part atthat location.2. Look at the service processor errorlog for more error information.3. Reseat the power supplies4. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V340110001 Power supply failed 1. If a location code is displayed withthis error code, replace the part atthat location.2. Look at the service processor errorlog for more error information.3. Reseat the power supplies4. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V35. Replace the system boardLocation: P1(See note 3 on page 109.)40110002 Missing voltage on both processor cards 1. If a location code is displayed withthis error code, replace the part atthat location.2. Look at the service processor errorlog for more error information.3. Reseat the power supplies4. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V340110003 Missing voltage on one processor card If AIX is running, check the AIX errorlog to find out which processor card isfailing. If AIX in not available, checkthe service processor error log.Replace the failing processor.Location: P1-C1 or P1-C2.136 Service Guide