Table 3. Firmware Error Codes. (continued)Error Code Description Action / Possible Failing FRU40110010 Current sharing fault detected in powersupply main enclosure1. If a location code is displayed withthis error code, replace the part atthat location.2. Reseat the power supplies3. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V340110011 DC_GOOD fault detected in main powersupply enclosure1. If a location code is displayed withthis error code, replace the part atthat location.2. Reseat the power supplies3. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V340110013 Only one power supply is present; twoare requiredInstall an additional power supply. Twopower supplies are required.40110014 Overcurrent detected on 5 volt line inpower supply main enclosure1. If a location code is displayed withthis error code, replace the part atthat location.2. Look at the service processor errorlog for more error information.3. Reseat the power supplies4. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V340111002 Unknown power problem detected. 1. If a location code is displayed withthis error code, replace the part atthat location.2. Replace the power suppliesone-at-a-time.Location: P3-V1Location: P3-V2Location: P3-V3140 Service Guide