Option settings Page 141 of 906Circuit Card Description and InstallationQPC559, QPC560 Loop Signaling Trunk cardsTable 48 and Table 49 on page 142 list option settings for loop signalingtrunk cards.Table 48QPC559, QPC560 single densityApplicationSingle density—Unit 0/1F30/F8 switch1 2 3 4 5 6Outgoing ANI only:loop pulsing off off off off off offbattery and ground pulsing off off off off on offOther than outgoing ANI on off on off on offJumpers (QPC560) Units 0/1/2/3600 ¾ resistive impedance connect pins 1 and 23-component complex impedance connect pins 2 and 3