Page 98 of 906 Acceptance tests553-3001-211 Standard 3.00 August 2005For other than an NT8D17 Conference/TDS card, enter:ENLL loop4 Test the TDS loop:TDS loopIf the system response is other than OK, see the Software Input/Output:Administration (553-3001-311) to analyze the messages.5 End the session in LD 34:****6 Using a maintenance telephone, log into the system.See “Communicating with the Meridian 1” in the Software Input/Output:Administration (553-3001-311) for details on accessing the system usinga maintenance telephone.7 From the maintenance telephone, enter:LD#34##To test outpulsers and channels for the TDS loop, see Table 13 onpage 98 for a sample of the input commands used with the maintenancetelephone. See the Software Input/Output: Administration(553-3001-311) for all tones that can be tested.8 Exit LD 34 from the maintenance telephone:****End of ProcedureTable 13TDS tone testsInput commandDial padequivalent DescriptionBSY#loop## 279#loop## Provides busy tone from TDS loop specified.C## 2## Removes any active tone.DIA#loop## 342#loop## Provides dial tone from TDS loop specified.OVF#loop## 683#loop## Provides overflow tone from TDS loop specified.RBK#loop## 725#loop## Provides ringback tone from TDS loop specified.