Page 616 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Table 190Jumper strap settings – factory standard (NT8D14BA, NT8D14BB)Trunk types Loop lengthJumper strap settings (Note 1)J1.X J2.X J3.XJ4.X(Note 2)CO/FX/WATS 0–1524 m (5000 ft.) Off Off 1–2 1–22-way TIE (LDR)2-way TIE (OAID)DID 0–600 ohms Off Off 1–2 1–2RAN: continuousoperation modeNot applicable: RANand paging trunksshould not leave thebuilding.Off Off 1–2 1–2PagingNote 1: Jumper strap settings J1.X, J2.X, J3.X, and J4.X apply to all eight units; “X” indicatesthe unit number, 0–7. “Off” indicates that no jumper strap is installed on a jumper block. Storeunused straps on the universal trunk card by installing them on a single jumper pin as shownbelow.Note 2: For the NT8D14BB card, J4.X is not provided on the card. The J4.X jumper settingspecified in Table 190 does not apply.Jumper pinJumper blockJumper strap553-6317