SETTING ITEMS (ADMIN)- 239 -2134567Setting the calibration display levelYou can set whether this equipment will use the calibrationsetting set by a user or the administrator.The relevant buttons ([CALIBRATION]) will appear under theADMIN menu only or under both the USER and ADMIN menusaccording to this setting.Setting the calibrationYou can automatically calibrate the gradation when the shading isnot reproduced accurately in the images scanned by this machine.Note• Whether to allow calibration by not only administrators butalso users, is set by DISPLAY LEVEL. P.239 "Setting the calibration display level"• Place LT or A4 paper (recommended paper) in the traybefore starting the calibration. If any other paper is used,calibration may not be performed properly.• If the glass is dirty or any foreign objects are stuck to it,calibration may not be performed properly. Keep the glass clean.• Do not raise the Reversing Automatic Document Feeder, oropen the front cover while the calibration is in progress. Ifthis does happen, calibration cannot be finished properly.• Interrupt copying is not available during the calibration.Memo• For instructions on how to display the CALIBRATIONscreen, see the following page: P.212 "Accessing the User Menu"1 Press [COPY].2 Select the paper type and press [OK].Note• Depending on the machine settings, the screen toselect the paper type may not be displayed. In thiscase, proceed to the next step.3 Select the calibration settings.4 Place the printed chart face down on theglass, so that the two black rectangularmarks are placed on the left side.5 Press the [START] button on the control panel.The calibration begins. Do not operate the equipmentuntil the message “Scanning and calibrating” disappears.Note• If the chart is not properly placed, the message “Setchart correctly” is displayed on the touch panel. In thiscase, return to step 3 and realign the chart.Setting the status messageYou can have a status message displayed at the bottom of thetouch panel, notifying the occurrence of specified events, suchas paper empty and toner low.Press [ON] or [OFF] for each status message and press [OK].Setting the auto clear functionYou can set how long the machine waits before clearing theprevious operation left uncompleted on the control panel.Press the desired period of time (in seconds). If you want todisable the Auto Clear function, press [NO LIMIT].Note• Selecting [NO LIMIT] does not clear the control panel for any modeincluding the SETTING, JOB STATUS, and TEMPLATE screens.Managing the option licensesYou can view product information, such as the license ID forcertain options. You can also install these options on theequipment if necessary. P.240 "Viewing product information" P.240 "Installing an option"For installation, be sure to follow the dealer’s instructions.Item name DescriptionCALIBRATION • USER — Press this button to display[CALIBRATION] in the ADMIN menuas well as the USER menu.• ADMIN — Press this button to display[CALIBRATION] in the ADMIN menu.Item name DescriptionDEFAULT Press this button to restore thedefault calibration setting and returnto the previous screen.CALIBRATION Press this button to calibrate usingthe printed chart. In this case,proceed to the next step.Item name DescriptionSUPPLIESNEAR LIFEMESSAGEEnabling this option displays a message atthe lower left of the screen when suppliessuch as toner, image drum, fuser unit andbelt unit nears the end of their lifespan.PAPER EMPTYMESSAGE Enabling this option displays a messageat the lower left of the screen when thereis no paper in a tray.