OfficeServ 7000 Series Call Server Programming Manual© SAMSUNG Electronics Co., Ltd. 2-223[702] TOLL DENY TABLEProvides a way to make toll restriction (call barring) very easy and flexible. There are 500entries allowed in the deny table and each entry index can be assigned to a class of service.Each index can have up to 12 digits. With the use of wild cards (MMC 704, Assign WildCharacter), more flexibility can be built into toll restriction. Wild cards can be usedrepeatedly in the dial string, limited only to what is allowed or denied in MMC 704.Six toll levels, B to G, are programmable. Toll level A is set as ‘unrestricted’ by default andtoll level H is set as ‘in-house only’ by default.DEFAULT DATAALL ENTRIES ARE SET TO 0PROGRAM BUTTONSA Used to enter wild card XB Used to enter wild card YC Used to enter wild card ZACTION DISPLAY1) Press Transfer button and enter 702.Display shows:DENY (001):BCDEFG:0000002) Dial index number. (e.g., 005)ORDENY (005):BCDEFG:000000Press Volume button to select index and press RightSoft button to move cursor.3) Enter toll pattern via dial keypad. (e.g., 212) DENY (005):BCDEFG212 :000000OREnter wild card (e.g., 21X) and press Right Softbutton to move cursor to COS options.DENY (005):BCDEFG21X :0000004) Press Volume button to move cursor along line untilunder toll class mark. (e.g., E).DENY (001):BCDEFG212 :000100Enter a 1 for ‘Yes’ or 0 for ‘No’.Press Right Soft button to store and return to step 1.ORPress Left Soft button to return to step 2.