OfficeServ 7000 Series Call Server Programming Manual© SAMSUNG Electronics Co., Ltd. 2-401[843] MPS OPTIONSThis MMC provides network configuration of MPS (Media Proxy Server) in the system.This option can be shown in some OfficeServ system.No Parameter Description0 LOCATION Located Cabinet and slot number of MPS.1 IP ADDRESS Specifies the IP address for the MPS.2 GATEWAY Specifies the designated IP gateway address used for contacting IPdevices beyond the local subnet.3 SUB MASK Specifies the IP subnet mask. This parameter is used by the system tocalculate the range of IP devices (subnet) that are within ‘direct reach’ of theMPS. (without having to go through the designated network IP gateway)4 IP TYPE Specifies if the system will be routing data over a public or privatenetwork.5 LOCAL RTP Local RTP Port6 CARD RESET Reboots MPS7 PUBLIC IP1 Pulbic IP Address is only used for VoIP signaling protocols in a NATnetwork . NAT system binds IP Address with Public IP and processes avoice stream. See System IP Type on MMC 8308 PUBLIC RTP1 Public RTP Port which NAT system binds a private RTP port with9 PUBLIC IP2 Pulbic IP Address is only used for VoIP signaling protocols in a NATnetwork . NAT system binds IP Address with Public IP and processes avoice stream. See System IP Type on MMC 83010 PUBLIC RTP2 Public RTP Port which NAT system binds a private RTP port with11 PUBLIC IP3 Pulbic IP Address is only used for VoIP signaling protocols in a NATnetwork . NAT system binds IP Address with Public IP and processes avoice stream. See System IP Type on MMC 83012 PUBLIC RTP3 Public RTP Port which NAT system binds a private RTP port with13 IP VERSION Specifies MPS IP version is IPv4 / IPv6.If MP-MPS (the embedded MPS) is selected, parameters such as IP ADDRESS,GATEWAY, SUB MASK, CARD RESET can not be set in this MMC becausethese parameters and the system values are the same.The system values can be referred in MMC 830.CONDITIONSThis MMC cannot be accessed unless MMC861 MPS SERVICE is enable.