INSTALLATION AND CONNECTIONS3English 15When connecting multiple devices, it is necessary to maketermination settings on both end devices.z Set the RS-485 termination switch of both end devices toON.z Be sure to set the RS-485 termination switches of alldevices in between (devices other than the first and lastdevices) to OFF.z If the termination settings are not correctly made, theincorrect data is transmitted to each device.Connect camera to the 2ND RS485/422 terminal with atwisted-pair cable and perform settings in the CONTROL SET> screen (JP.150) to control the camera withthe connected system controller or with the digital videorecorder.z Connect as shown above and set to full screen in the screen to control camera withthe digital video recorder.z If connected as shown above, settings must be made in screen.z Connect other companies’ cameras to the 2ND RS-485/422 terminals.1 Connect as above.Connect SSP dome cameras to VIDEO IN 1 and 2.2 Set the camera numbers and protocolsin the screen. (JP.150)3 Operate the dome cameras with thefront panel buttons. (JP.153)RS-485 termination switch settingsRS-485TERMINATEOFF ONTERMINATERS-485OFF ONTERMINATERS-485OFF ONVIDEOCOMSWON1 2 3 4A BTELEMETRY12VSWON1 2 3 4System controllerTerminationswitchDigital video recorderRS485TerminationswitchExample:RS485TerminationswitchConnecting to a 2ND RS485/422terminalOperationOther companies’ camerasSystemcontroller