PLC-WM5500/WM5500L Expand Serial Command Functional Specifications61/889.5.8 CR_ORGMODE CommandCommand “CR_ORGMODE” [CR]Details Get the original signal of current selected Mode that is set in PC Adj.When MODE1- 10 or EXT11-50 is not selected, get the current signal.Acceptable “000_%1” [CR]%1When input signal is PC Analog;“VGA1” ------------------------ Indicates signal Is VGA1“VGA2” ------------------------ Indicates signal is VGA2::“XGA1” ------------------------ Indicates signal is XGA1::“WXGA3” --------------------- Indicates signal is WXGA3“1080I60” --------------------- Indicates signal is 1080i60“1080I50” --------------------- Indicates signal is 1080i50“1035I” ------------------------ Indicates signal is 10350i“720P60” --------------------- Indicates signal is 720p60“720P50” --------------------- Indicates signal is 720p50“575P” ------------------------- Indicates signal is 575p“480P” ------------------------- Indicates signal is 480p“575I” -------------------------- Indicates signal is 575i“480I” -------------------------- Indicates signal is 480i“1080PSF/24” ----------------- Indicates signal is 1080psf/24“1080PSF/25” ----------------- Indicates signal is 1080psf/25“1080PSF/30” ----------------- Indicates signal is 1080psf/30“1080P24” ----------------- Indicates signal is 1080p24“1080P25” ----------------- Indicates signal is 1080p25“1080P30” ----------------- Indicates signal is 1080p30“1080P50” ----------------- Indicates signal is 1080p50“1080P60” ----------------- Indicates signal is 1080p60Note; To differentiate between 60Hz and 50Hz in 1080i and 720p,“60” or “50” is necessary to add to the parameter in this command* When input signal is not PC Analog, error code “101” isreturned.ResponseUnacceptable “Error Code” [CR]