PLC-WM5500/WM5500L Expand Serial Command Functional Specifications64/889.7 Input Read Command9.7.1 CR_INPUT CommandCommand “CR_INPUT” [CR]Details Get selected INPUT No.Acceptable “000_%1” [CR]%1 “1 – 4”ResponseUnacceptable “Error Code” [CR]9.7.2 CR_SOURCE CommandCommand “CR_SOURCE” [CR]Details Get selected sourceAcceptable “000_%1” [CR]%1“ANALOG” -------------- RGB (PC Analog) is selected“SCART” ----------------- RGB (Scart) is selected“HDMI” --------------------HDMI is selected“VIDEO” ------------------ Video is selected“S-VIDEO” --------------- S-Video is selected“YPBPR” ----------------- Y,Pb/Cb,Pr/Cr is selected“NETWORK” ------------ Network is selectedResponseUnacceptable“Error Code” [CR] --- When command is not available in the givencondition (such as being selected input)“?” [CR] ---------------- When unknown command is received9.7.3 CR_SRCINP1 CommandCommand “CR_SRCINP1” [CR]Details Get Source of INPUT1Acceptable “000_%1” [CR]%1“ANALOG” ---------------------- in PC Analog mode“SCART” ------------------------ in Scart mode“HDMI” --------------------------- in HDMI modeResponseUnacceptable “Error Code” [CR]9.7.4 CR_SRCINP2 CommandCommand “CR_SRCINP2” [CR]Details Get Source of INPUT2Acceptable “000_%1” [CR]%1“VIDEO” --------------------- in Video mode“YPBPR” -------------------- in Y,Pb/Cb,Pr/Cr mode“ANALOG” ------------------ in RGB modeResponseUnacceptable “Error Code” [CR]