PLC-WM5500/WM5500L Expand Serial Command Functional Specifications69/889.7.15 CR_IDSLOT1 CommandCommand “CR_IDSLOT1” [CR]Details Get ID information of Input1. This command is to determine sources possible toinput.Acceptable “000_%1” [CR]%1 “30” --------------- On-board (HDMI and D-Sub)Available source: ANALOG, SCART, HDMIResponseUnacceptable “Error Code” [CR]9.7.16 CR_IDSLOT2 CommandCommand “CR_IDSLOT2” [CR]Details Get ID information of Input2. This command is to determine sources possible toinput.Acceptable “000_%1” [CR]%1 “41” --------------- On-board (5BNC)Available source: ANALOG, VIDEO, YPBPRResponseUnacceptable “Error Code” [CR]9.7.17 CR_IDSLOT3 CommandCommand “CR_IDSLOT3” [CR]Details Get ID information of Input3. This command is to determine sources possibleto input.Acceptable “000_%1” [CR]%1 “51” --------------- On-board (3BNC and S-VIDEO)Available source: VIDEO, S-VIDEO, YPBPRResponseUnacceptable “Error Code” [CR]9.7.18 CR_IDSLOT4 CommandCommand “CR_IDSLOT4” [CR]Details Get ID information of Input4. This command is to determine sources possibleto input.Acceptable “000_%1” [CR]%1“13” --------------- PJ-Net (Viewer capable)Available source: Network*With PJ-Net unattached, this command is invalid and errorcode “103” is returned.*With PJ-Net attached and the power OFF, error code “101” isreturned.*In models not supporting PJ-Net, error code “103” is returned.ResponseUnacceptable “Error Code” [CR]