4 - Module operations—MODULE screen (miscellaneous)4–114.11.1Global delay settingUse POD 1 of the last row to set the value and copy itto all busses (right switch of POD 1) for the “global”buss delay:Confirm the setting with the ENTER key or cancelwith a cursor key.4.12MODULE screen(miscellaneous)In the MODULE screen, a meter is shown to theright of the screen:4.12.1Meter pickoff pointImmediately below the meter is a description show-ing the “pickoff” point for the meter (POST-EQin the illustration above).Move the cursor to this description and press theENTER key to cycle through the following pickoffpoints: POST-EQ (after the equalization),POST-DYN (following the dynamics processor)or POST-FADER (after the channel fader).This also applies to the STEREO OUT. In this case,only the on-screen meters are affected. If this buss isselected for monitoring using the hardware meters,the meter readings will not be changed by thisoperation.4.12.2Other informationThe MODULE screen also shows the current faderand cut group assignment for the module (see 4.9,“Fader and cut groups”), the group assignments (anddirect output assignment if appropriate).A representation of the current fader position is alsogiven, together with the fader level, relative to thenominal level. The cut status is also shown, immedi-ately above the fader representation.4.13SoloingModules may be soloed by pressing the SOLO key ofa module.The exact action taken depends on the solo modecurrently selected, as well as the Inplace Defeat set-ting for the module and other modules.See 5.4, “SOLO” for details of solo settings andoperations.