10 Input Assemblies (Drive Produces)52 YASKAWA ELECTRIC SIEP C730600 43A YASKAWA AC Drive-Option Card DeviceNet Technical ManualNote: Refer to the MEMOBUS/Modbus Data Table in Appendix C of the technical Manual for the drive the DeviceNet Option isconnected to for a list of monitor data using the MEMOBUS/Modbus message area.ZSPZero Speed0: Running1: Stop or DC Injection BrakingREV RunningReverse Running0: Not Reverse Running1: Reverse RunningResetReset0: No Reset1: ResetSpeed AgreeSpeed Agree0: No Speed Agree1: Actual speed at speed referenceREADYDrive Ready0: Not Ready1: ReadyALARMDrive Alarm0: No Drive Alarm1: AlarmFAULTDrive Fault0: No Drive Fault1: FaultMulti-Function Input 1Terminal S10: Terminal S1 OFF1: Terminal S1 ONMulti-Function Input 2Terminal S20: Terminal S2 OFF1: Terminal S2 ONMulti-Function Input 3Terminal S30: Terminal S3 OFF1: Terminal S3 ONMulti-Function Input 4Terminal S40: Terminal S4 OFF1: Terminal S4 ONMulti-Function Digital OutputTerminal M1/M20: Terminal M1/M2 OFF1: Terminal M1/M2 ONMulti-Function Photo Coupler 1Terminal P10: Terminal P1 OFF1: Terminal P1 ONMulti-Function Photo Coupler 2Terminal P20: Terminal P2 OFF1: Terminal P2 ONOutput FrequencyActual Drive SpeedMonitors drive output frequencyUnit depends on o1-03.Unit is not affected by Speed Scale SS.Actual CurrentActual Output CurrentMonitors drive output currentUnit is 0.01 A for drives set up to 11 kW in Heavy Duty or Normal Duty and 0.1 A for drives set up for 15kW and above.Unit is not affected by Current Scale CS.Parameter Data