COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 4 IMAGE FORMATION SYSTEM4-9 P• Standard Mode (selected in service mode)The two types of potential control (for copying and printing) are executed in succession:F04-201-04COPIER>OPTION>BODY>PO-CNT (turning on/off potential control)0: potential control OFF1: potential control ON (default)COPIER>OPTION>BODY>PO-CNTMD (selecting potential controlmode)0: 10 min, 60 min potential control OFF (default)1: 10 min, 60 min reduced mode2: 10 min, 60 min normal modeCOPIER>OPTION>TEMPO>F-POT-SWIf transfer separation faults occur because of a fault (error) in the potentialsensor, enter ‘1’.Use it as an emergency remedy until the potential sensor is replaced.COPIER>OPTION>TEMPO>F-POT-DIt becomes valid when ‘1’ is set to COPIER>OPTION>TEMPO>F-POT-SW.0: for text-oriented users (originals with low image ratio; default)1: for photo-oriented users (originals with high image ratio)2: to prevent re-transfer (white spots near 50 mm of leading edge)COPIER>OPTION>TEMPO>F-HUM-SWEnter ‘1’ if the environment sensor is faulty (out of order).Use it as an emergency remedy until the environment sensor is replaced.COPIER>OPTION>TEMPO>F-HUM-DIt becomes valid when ‘1’ is set to COPIER>OPTION>TEMPO>F-HUM-SW.Enter the humidity reading of the site of installation. (adjustment range:30% to 99%; default: 35%)Potentialcontrolfor copyingPotentialcontrolfor printingFixing assembly temperature 195˚C(end of fixing assembly warm-up)Control panel power switch ONStart keyON Potential control Potential controlStart key ON10 min later tobefore 60 min60 min and laterPotential controlfor copying andprinting duringthe first jobPotential controlfor copying andprinting duringthe first job