COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 3 STANDARDS AND ADJUSTMENTS3-20 T4.15 Position of the Side Paper Deck Pickup Roller ReleasingSolenoidBefore removing the deck pickup roller releasing solenoid [1] from the support plate, takenote of the position of the two fixing screws [2] of the solenoid with reference to the indexon the support plate. Or, draw a line on the support plate so that it will serve as a referencewhen positioning the solenoid.When mounting the solenoid on its own, be sure to secure it in its original position.F03-415-014.16 Attaching the Timing Belt of the Manual Feed TrayAssembly1) Butt the rack plate [1] of the manual feed tray against A (open state}.2) Move the slide volume in the direction of B, and attach the timing belt [2] to the pulley[3].F03-416-01[2] [1]AB[3][2] [1]