COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 4 IMAGE FORMATION SYSTEM4-24 P3.4.2 Controlling the Output to Suit the Environment (fuzzy control)The pre-transfer charging current is optimized in relation to the site conditions (i.e., baseon the data from the environment sensor).F04-304-02COPIER>OPTION>BODY>FUZZY (turning on/off fuzzy control)0: fuzzy control ON (default)1: low humidity mode (uses a lower-than-standard pre-transfer chargingcurrent)2: normal humidity mode3: high humidity mode (use higher-than-standard pre-transfer chargingcurrent)Setting it to ‘1’ through ‘3’ will make the control independent of the read-ing from the environment sensor.Low humidity‹ fiHigh humidityPre-transfercurrent-10-260