COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 6 FIXING SYSTEM6-39 P4.7 Paper Sensor4.7.1 Removing the Claw Jam Sensor1) Remove the fixing assembly from themachine.2) Remove the two screws from the lowerseparation claw assembly.3) Remove the internal delivery roller.4) Remove the mounting screw [1], anddetach the sensor together with its sup-port plate [2].F06-407-015) Disconnect the connector [3], and re-move the snap-on assembly; then, de-tach the claw jam sensor [4].F06-407-024.7.2 Removing the Internal Delivery Sensor1) Remove the fixing assembly from themachine.2) Remove the two screws, and detach thelower separation claw assembly.3) Remove the internal delivery roller.4) Remove the mounting screw [1], anddetach the sensor together with its sen-sor support plate [2].F06-407-03[2][1][4][3][1][2]