COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 6 FIXING SYSTEM6-36 P4.6 Delivery Assembly4.6.1 Removing the External Delivery Roller1) Remove the fixing/feeding unit out ofthe machine. Remove the two screws[1], and detach the delivery roller guide[2].F06-406-012) Remove the screw [3] and the bushing[4]; then, detach the delivery unit [5].3) Remove the E-ring [6] at the front, anddetach the bearing [7].F06-406-024) Slide the external delivery roller assem-bly [8] toward the rear to detach.F06-406-03[1] [2] [1][3][4][5] [7] [6][8]