COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 3 INSTALLATION3-18 SSlide out the duplexing unit and check to make sure that there is no foreign matterand each part is free of damage.Connect the power plug to the power outlet and turn on the power switch.• Adjust the contrast of the control panel display using the Screen Contrast key;then advise the user on how to make adjustments.• Check that the Add Paper indicator has turned on.• Press the keys of the keypad and the Clear key to make sure that the copy countindication is correct.Place paper in the cassettes and the deck. (If the paper size has been changed for thedeck, be sure to register the new paper size using service mode.)When the wait period is over, start service mode and execute toner supply (therebysupplying toner from the hopper to the developing assembly).1. Press the following in sequence to start service mode: ‘user mode’, ‘2 and 8 atthe same time’, and ‘user mode’.2. Select COPIER>FUNCTION>INSTALL>TONER-S.3. Check that the following indication has appeared: “CHECK THE DEVEL-OPER.”4. Check to make sure that the developing assembly has been mounted properlyand press the OK key.5. See that toner is supplied from the hopper to the developing assembly (about 8to 10 min).6. Press the Reset key twice to end service mode.Do not turn off the power while the machine is in operation.Checks/remarksStep1234Work2.13 Checking Images/Operations and User ModeBe sure to remove all packaging material from the cassettes before turningon the power switch.