COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 6 SELF DIAGNOSIS6-16 TE535Main Cause The swing motor clock sensor (PI20) is faulty. The swing guide open sen-sor (PI18) is faulty. The safety area switch (MS3) is faulty. The swing guideclosed detecting switch 2 (MS6) is faulty. The swing motor (M7) is faulty.The finisher controller PCB is faulty.Mode ofDetection0001 The swing guide closed detecting switch 2 does not turn on whenthe swing motor has been rotated CCW for 1 sec.0002 The swing guide open sensor does not turn on when the swing mo-tor has been rotated CW for 1 sec.0003 When the tray lift motor is in operation, the swing guide closed de-tecting switch 2 is found to be off while the tray 1/2 is at OFF posi-tion of the safety area switch.0004 No clock arrives for 200 msecs while the machine is in swing op-eration.E540Main Cause The tray home position sensor (PI8) is faulty. The tray lifter motor clocksensor 1/2 (PI9/PI19) is faulty. The tray upper limit detecting switch (MS5)is faulty. The tray lifter motor (M5) is faulty. The finisher controller PCB isfaulty.0001 The ascent does not end in 15 secs when the tray lift motor isdriven; or, the tray home position cannot be detected when the traylift motor has been driven for 15 secs.0002 While the tray is moving up, the tray upper limit detection switchis found to be on.0003 When the tray lift motor is driven, clock pulses do not arrive fromthe clock sensor 1/2 for 200 msecs.E584Main Cause The shutter open sensor (PI5) is faulty. The safety area detecting switch(MS3) is faulty. The shutter closed detecting switch (MS4) is faulty. TheNo. 2 feed motor (M8) is faulty. The finisher controller PCB is faulty.Mode ofDetection0001 The shutter closed detecting switch does not turn on when the No.2 feed motor has been rotated CCW for 1 sec or more.0002 The shutter open sensor does not turn on when the No. 2 feed mo-tor has been rotated CCW for 1 sec.0003 While the tray lift motor is in operation, the shutter closed detect-ing switch is found to be off when the tray 1/2 is at OFF positionof the safety area detecting switch.